News

Increased system efficiency with floor circuit balancing

Underfloor heating systems are an increasingly popular solution for heating homes because of their ability to provide even heat and excellent comfort. 

To get the most out of this solution, it is essential to ensure that the circuits are correctly balanced.

In this guide we will look at the process of loading and balancing the circuits of a radiant system using Luxor manifolds.

Why is it important to balance the underfloor system?

An unbalanced radiant system can cause uneven heat distribution.

This means that some rooms may be warmer while others remain cold, affecting the overall comfort of the home. 

An unbalanced system also operates inefficiently, increasing energy consumption and running costs.

Circuit balancing therefore allows water to be evenly distributed across all circuits in the system, ensuring the correct temperature in each area of the house.

How to balance the circuits of a radiant system

With Luxor distribution manifolds, equipped with integrated fill and drain angle valves, balancing the system becomes a quick and easy process, providing a convenient and intuitive solution for plumbers and installers.

  • System preparation

Once the manifolds have been installed, ensure that all the inlet valves are closed. This step is essential to control the flow of water in each circuit and to ensure proper charging.

  • Loading the circuits

Connect the fill and drain pipes to the manifolds using the integral angle valves. Open the fill and drain valves one at a time to allow the fluid to completely fill each circuit. 

This process eliminates any air bubbles that could affect the functioning of the system.

  • Adjusting the flow

Once all the circuits have been loaded, it is time to balance them.

Luxor manifolds offer various solutions for this phase, such as lockshields or flow regulators and meters, to ensure simple and precise regulation of the water flow for each circuit in the system.

  • Checking stability

After balancing the circuits, it is important to check the stability of the settings. This can be done by monitoring the system for a few hours and making corrections if necessary.

The benefits of Luxor manifolds

In summary, Luxor manifolds offer plumbers and installers a convenient and safe solution for balancing the underfloor circuit, ensuring efficient thermal control throughout the home.

The integrated inlet/outlet angle valves help to manage the flow of water, reducing the risk of installation errors, while 100% leak testing of the manifolds ensures maximum resistance to temperature and pressure.

Want to learn more about how to properly balance a floor system? Check out the video on our YouTube channel.